S7-200/300/400 Ethernet programming connector

511,00  excluding VAT

S7-SPS remote maintenance, programming, and visualization via Ethernet

– Connection via any free PROFIBUS/MPI/PPI port
– Cost-effective alternative to original S7 Ethernet CPs
– Automatic driver integration into any S7 engineering tool
– Easy coupling of two PLCs without Ethernet interface
– Immediate coupling of S7-compatible HMI devices via Ethernet
– Effortless access via applications developed by the customer, e. g. C++, C#

25 skladem

x
SKU: NL 50-MPI Categories: Tags:
YOU MAY ALSO LIKE...
YOUR ADVANTAGES

30-day right of return

3 Year warranty

Global delivery

Learn more about levtech!

As directly mountable or firmly attachable DIN rail devices, the adapters netLINK-MPI and netTAP-MPI replace expensive CP communication processors and allow programming, visualizing, and controlling S7-200®, S7-300®, or S7-400® PLCs via Ethernet.

The delivered driver can be integrated as a programming device (PG) into all well-known SIMATIC S7® engineering tools like STEP7® or TIA portal. The device is set up with the engineering tool or using conventional web browsers via the embedded web server.

The adapters are suitable to program or change S7-PLC control programs and to design HMI devices with the visualization software WinCC. Ethernet protocol “ISO on TCP” RFC1006 supports the coupling of any third party or SIMATIC® visualization station with the PLC. Once integrated into the plant or company network and connected to the internet, remote maintenance, and logging via a router across network boundaries with standard TCP/IP protocol are possible, too.

Organized in a network, direct communication between two or several PLCs via Ethernet can be realized. PLCs can even be coupled without Ethernet port. Fully integrated PROFIBUS diagnostics and Master Class 2 DPV1 services allow the complete DP Slave device configuration and parameterization in STEP7®.

Power is supplied by a 24 V DC connector. The S7 PLC directly supplies the netLINK-MPI connector with power. Since the contacts of connector and socket are connected with each other 1-to-1, the netLINK-MPI connector allows the trouble-free operation of further devices at the same MPI/DP bus.

NL 50-MPI supports the following protocols:

– Ethernet
– PROFIBUS MPI/DP/PPI

For detailed technical documentation, please visit the following page:
https://www.hilscher.com/products/gateways-switches-for-industrial-communication/gateways-for-industrial-ethernet-fieldbus-serial/nl-50-mpi

Product name

NL 50-MPI

Part number

1701.430

Brief description

S7-200/300/400 Ethernet Programming Connector

Function

Monitoring, programming and visualizing S7-PLCs over Ethernet

Type

netX 50

RAM

8 MB SDRAM

FLASH

4 MB serial flash, with boot loader, firmware und configuration

Supply voltage

24 V DC ± 6 V DC

Current (typically)

57 mA (at 24 V), 72 mA (at 18 V), 48 mA (at 30 V)

Connector

Connector for power supply from PLC: via D-Sub plug from PLC, 9-pin

Connector for external power supply

Mini-COMBICON socket, 3.81 mm, 2-pin

Communication interface 1 - Communication standard

PROFIBUS

Communication interface 1 - Interface type

RS-485, non-isolated (for hardware revision 2 and 3), isolated (from hardware revision 4)

Communication interface 1 - Connector

D-Sub plug, 9-pin; D-Sub socket, 9-pin, as interface for a S7 programming tool with 1:1 connection

Communication interface 2 - Communication standard

Ethernet

Communication interface 2 - Interface type

10BASE-T/100BASE-TX, isolated

Communication interface 2 - Auto negotiation

supported

Communication interface 2 - Auto cross over

supported

Communication interface 2 - Connector

RJ45 socket

LED display

SYS, System status
COM, Communication status
LNK, Ethernet link status
ACT, Ethernet activity status

Operating temperature range

0 °C … +55 °C

Humidity

0 % … 85 % relative humidity (not condensing)

Dimensions (L x W x H)

74.3 mm x 40.6 mm x 16.7 mm

Weight

approx. 40 g

Protection class

IP 20

Mounting/Installation

directly on PLC

Configuration software

SyCon MPI or IBHnet-Treiber

RoHS

yes

CE sign

yes

Electrostatic discharge (ESD) according to IEC/EN 61000-4-2:1995 (Air discharge method)

10 kV, Criterion A

Electrostatic discharge (ESD) according to IEC/EN 61000-4-2:1995 (Contact discharge method)

4 kV, Criterion B

Fast transient interferences (Burst), zone B, according to IEC/EN 61000-4-4:1995

1 kV Power supply connectors DC, Criterion B; 1 kV Communication and data lines, Criterion A

Surge voltage, zone B, according to IEC/EN 61000-4-5:1995

1 kV CM, 0,5 kV DM Power supply connectors DC, Criterion B; 1 kV CM Communication and data lines, Criterion B

Recenze

Zatím zde nejsou žádné recenze.

Pouze přihlášení uživatelé, kteří zakoupili tento produkt, mohou přidat hodnocení.

DOCUMENTATION
RECENT REVIEWS
Levtech Service & Production
Přehled ochrany osobních údajů

Tyto webové stránky používají soubory cookies, abychom vám mohli poskytnout co nejlepší uživatelský zážitek. Informace o souborech cookie se ukládají ve vašem prohlížeči a plní funkce, jako je rozpoznání, když se na naše webové stránky vrátíte, a pomáhají našemu týmu pochopit, které části webových stránek považujete za nejzajímavější a nejužitečnější.