Pulse counter

Prețul inițial a fost: 110,00 €.Prețul curent este: 100,00 €. fără TVA

Four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

50 în stoc

Cantitate Reducere (%) Preț
1 - 9 - 100,00 
10+ 10 % 90,00 
x
VĂ POATE PLĂCEA, DE ASEMENEA...
AVANTAJELE DUMNEAVOASTRĂ

30 de zile drept de retur

Garanție de 3 ani

Livrare globală

Aflați mai multe despre levtech!

Four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

Caracteristici
* four independent counters
* counter input designed to work with AC/DC signals
* factor adjustment (a floating-point value)
* rescaled value (number of pulses × factor)
* selecting a mode of state 1 trigger: high or low voltage
* selecting an input pulse edge (leading or trailing)
* frequency filter that allows you to limit the maximum frequency of counted pulses (to eliminate interferences on the input of the counter)
* memory of counter status after power failure
* digital input
Operation
The MB-LI-4 module is a four-channel one-way counter. Each channel is independent and counts the impulses in accordance with individual settings. The results are presented in the form of a number of pulses and rescaled value in a range from 0 to ~4, 29 billion.  Reading of the counter can be reset independently for each channel. Once the maximum number of pulses (overflow) is reached, counter automatically resets and counts from 0. The module has configurable options of counting pulses with low (0 V) or high (V+) signal and with leading or trailing edge.
In addition, counting input can be used as a DI digital input with the ability to read its state.
Reading the values of counted pulses, a rescaled value, adjustment of all counting parameters, communication and data exchange is carried out via RS-485 port using MODBUS RTU communication protocol. Power is indicated by a green LED U light. Correct data exchange between the module and other device is indicated by the LED yellow Tx light.

ATTENTION!

External control voltage is needed in each case to trigger input. If the module power supply is used to this end, it results in the loss of galvanic separation between control inputs, power supply and communication.

 

Connection scheme

Implementation of connecting counting and digital inputs

Setting the network address

Power supply voltage

9÷30 V DC

Protocol de comunicare

MODBUS RTU

Stop bits

1 / 1.5 / 2

ports

RS-485

The voltage of the counting input

6÷30 V AC/DC

Max. Counting frequency

100 Hz

Number of digital inputs

4

The type of work

SLAVE

Baudrate

1200÷115200 bit/s

Data bits

8

Bits of parity

EVEN / ODD / NONE

Adresa

1÷247

Terminal

pluggable terminal blocks 2,5 mm²

Tightening torque

0,4 Nm

Consumul de energie

0,3 W

Working temperature

-20÷50°C

Dimensiuni

1 module (18 mm)

Assembly

on rail 35 mm

Ingress Protection Marking

IP20

Recenzii

Nu există recenzii până acum.

Numai clienții autentificați, care au cumpărat acest produs, pot să scrie o recenzie.

DOCUMENTATION
RECENT REVIEWS
Levtech Service & Production
Prezentare generală a confidențialității

Acest site folosește cookie-uri pentru a-ți putea oferi cea mai bună experiență în utilizare. Informațiile cookie sunt stocate în navigatorul tău și au rolul de a te recunoaște când te întorci pe site-ul nostru și de a ajuta echipa noastră să înțeleagă care sunt secțiunile site-ului pe care le găsești mai interesante și mai utile.